
Journal of Spine Practice
ISSN: 2789-9462
Leading research in all spine subspecialties focusing on orthopaedic spine, neurosurgery, radiology, and pain management.
Are Self-Drilling, Self-Tapping Screws Effective in Anterior Cervical Fusion Surgery? One Surgeon’s Experience with 50 Consecutive Patients
Published date:Mar 13 2025
Journal Title: Journal of Spine Practice
Issue title: Journal of Spine Practice (JSP): Volume 4, Issue 2
Pages:1 - 10
Authors:
Abstract:
Purpose
Even though plate and screw designs in anterior cervical discectomy and fusion (ACDF) have evolved to improve fusion stability and enhance patient outcomes, some argue that pre-tapping remained the best option. The purpose of this study is to evaluate the outcomes and complications of self-drilling, self-tapping screws and evaluate their efficacy in maintaining instrumentation position in plated ACDFs.
Methods
In this retrospective case series, patients who underwent ACDF with plating and selfdrilling, self-tapping screws from February 2021 to May 2023 were consecutively included. Demographic, radiographic, intraoperative, and postoperative data were collected. Odds ratios (ORs) were also utilized to determine factors associated with abnormal C2-C7 Cobb angles and C2-C7 sagittal vertical axes (SVAs) postoperatively.
Results
A total of 50 patients (26M, 24F, mean age: 56.7 ± 10.4) were included. At the final postoperative radiographic follow-up (251.1 ± 226.5 days), the C2-C7 Cobb angle increased by 21.03%, with the C2-C7 SVA increasing by 3.25%. OR assessment found an association with the American Society of Anesthesiologists (ASA) physical status classification score of ≥ 3 and abnormal postoperative C2-C7 SVA (5.667, 95% CI: 1.067 to 30.086, p=0.042). Longer operative times (≥91.5 minutes) were less likely to be associated with abnormal postoperative C2-C7 Cobb angles when compared to shorter operative times (0.175, 95% CI: 0.032 to 0.952, p=0.044). No fixation system complications or evidence of radiographic or clinical pseudoarthrosis were noted.
Conclusion
Patients undergoing ACDF with self-drilling, self-tapping screws had excellent postoperative outcomes and no evidence of instrumentation complications, including pseudoarthrosis. This case series demonstrates the safety of ACDF with this screw design. However, future studies should include a larger cohort of patients to provide more accurate guidelines and recommendations.
Keywords: radiographic outcomes, implant complications, self-drilling, self-tapping screws, self-drilling screws, anterior cervical discectomy and fusion
References:
[1] Spivak JM, Chen D, Kummer FJ. The effect of locking fixation screws on the stability of anterior cervical plating. Spine (Phila Pa 1976). 1999;24(4):334-338. doi:10.1097/00007632- 199902150-00005
[2] Porto MA, Silva P, Rosa R, et al. Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws. Eur Spine J. 2012;21(5):956-963. doi:10.1007/s00586- 011-2120-z
[3] Hitchon PW, Brenton MD, Coppes JK, From AM, Torner JC. Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws. Spine (Phila Pa 1976). 2003 Jan 1;28(1):9-13. doi: 10.1097/00007632-200301010- 00004. PMID: 12544947.
[4] Heller JG, Estes BT, Zaouali M, Diop A. Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance. J Bone Joint Surg Am. 1996;78(9):1315-1321. doi:10.2106/00004623-199609000-00004
[5] Cloward RB. The anterior approach for removal of ruptured cervical disks. 1958. J Neurosurg Spine. 2007;6(5):496-511. doi:10.3171/spi.2007.6.5.496
[6] Martini ML, Neifert SN, Chapman EK, Mroz TE, Rasouli JJ. Cervical Spine Alignment in the Sagittal Axis: A Review of the Best Validated Measures in Clinical Practice. Global Spine J. 2021;11(8):1307- 1312. doi:10.1177/2192568220972076
[7] Chung JY, Kim SK, Jung ST, Lee KB. Clinical adjacent-segment pathology after anterior cervical discectomy and fusion: results after a minimum of 10-year follow-up. Spine J. 2014;14(10):2290-2298. doi:10.1016/j.spinee.2014.01.027
[8] Mobbs RJ, Rao P, Chandran NK. Anterior cervical discectomy and fusion: analysis of surgical outcome with and without plating. J Clin Neurosci. 2007;14(7):639-642. doi:10.1016/j.jocn.2006.04.003
[9] Nambiar M, Phan K, Cunningham JE, Yang Y, Turner PL, Mobbs R. Locking stand-alone cages versus anterior plate constructs in singlelevel fusion for degenerative cervical disease: a systematic review and meta-analysis. Eur Spine J. 2017;26(9):2258-2266. doi:10.1007/s00586-017- 5015-9
[10] Lambrechts MJ, Maryan K, Whitman W, et al. Comorbidities associated with cervical spine degenerative disc disease. J Orthop. 2021;26:98-102. Published 2021 Jul 16. doi:10.1016/j.jor.2021.07.008
[11] Kumar VK, Prasad K, Sansgiri T, Ranganath K, Shwetha V, Al-Khuteja K. Self-Drilling Versus Self- Tapping Screws: A 3D Finite Element Analysis. Craniomaxillofac Trauma Reconstr. 2021;14(1):4- 10. doi:10.1177/1943387520904212
[12] Silva P, Rosa RC, Shimano AC, Albuquerque de Paula FJ, Volpon JB, Aparecido Defino HL. BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN. Rev Bras Ortop. 2015;44(5):415-419. Published 2015 Dec 8. doi:10.1016/S2255-4971(15)30272-X
[13] Porto MA, Silva P, Rosa R, et al. Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws. Eur Spine J. 2012;21(5):956-963. doi:10.1007/s00586- 011-2120-z
[14] Conrad BP, Cordista AG, Horodyski M, Rechtine GR. Biomechanical evaluation of the pullout strength of cervical screws. J Spinal Disord Tech. 2005;18(6):506-510. doi:10.1097/01.bsd.0000140196.99995.65
[15] Goelzer JG, Avelar RL, de Oliveira RB, Hubler R, Silveira RL, Machado RA. Self-drilling and self-tapping screws: an ultrastructural study. J Craniofac Surg. 2010;21(2):513-515. doi:10.1097/SCS.0b013e3181d023bd
[16] Harel R, Kimchi G, Knoller N. One-step insertion of navigated pedicle screws in minimally invasive transforaminal lumbar interbody fusion (MITLIF): preliminary results of a novel technique. Br J Neurosurg. 2021;35(6):753-756. doi:10.1080/02688697.2020.1777257
[17] Crawford NR, Yüksel KZ, Doğan S, et al. Trajectory analysis and pullout strength of self-centering lumbar pedicle screws. J Neurosurg Spine. 2009;10(5):486-491. doi:10.3171/2009.1.SPINE08274
[18] Wu Z, Nassar SA, Yang X. Pullout performance of self-tapping medical screws. J Biomech Eng. 2011;133(11):111002. doi:10.1115/1.4005172