KnE Materials Science
ISSN: 2519-1438
The latest conference proceedings on physical materials, energy materials, electrical materials.
Evaluation of Entre-os-Rios Thermal Aquifer Vulnerability Using DRASTIC Index
Published date: Aug 10 2022
Journal Title: KnE Materials Science
Issue title: 1st International FibEnTech Congress (FibEnTech21) – New Opportunities for Fibrous Materials in the Ecological Transition
Pages: 234–243
Authors:
Abstract:
The “Entre-os-Rios” thermal aquifer has a protection perimeter buffer zone for avoiding water contamination. A vulnerability map was generated, using geographic information systems (GIS) tools and the DRASTIC index, to evaluate the risk of contamination of the perimeter area. The results showed that the protection perimeter buffer zone has an insignificant to moderate risk of pollution, with the DRASTIC index’s values ranging from 47 to 127 points, and an average pollution vulnerability of 79 points. The alluvium-covered land is vulnerable to moderate contamination but is located far from the catchment point. Areas of minimal risk correspond to locations where the granitic massif has not been altered significantly.
Keywords: geographic information systems, vulnerability map, protection perimeter buffer zone, DRASTIC index
References:
[1] Ferreira MRN. Evolução hidrogeoquímica das águas sulfúreas de Entre-os-Rios: Avaliação preliminar [Tese de Mestrado]. Instituto Superior de Engenharia do Porto; Porto, 2013.
[2] Diário da República. Portaria no. 203/2003 de 7 de março do diário da República n.º 56/2003, Série I-B. Fixa o perímetro de protecção da água mineral natural a que corresponde o número HM-23 de cadastro e a denominação de Entre-os-Rios (Quinta da Torre).
[3] Lopo de Mendonça J, Cabral, J. Identificação de falhas na Bacia Cenozóica do Tejo através de técnicas de investigação hidrogeológica. Comunicação Instituto Geológico e Mineiro. 2003; 90:91-102.
[4] Aller L, Bennet T, Lehr J, Petty R. DRASTIC: A standardized system for evaluating groundwater pollution potential using hydrogeologic settings. US EPA US EPA Report, 600/2–87/035, Robert S. Kerr Environmental Research Laboratory, Ada, OK, 1987.
[5] Gómez M. Caracterização da vulnerabilidade dos aquíferos à contaminação dos aquíferos. Aplicação dos índices DRASTIC e GOD. Madrid: Centro de Estudos e Experimentação de Obras Públicas; 1998.
[6] Lobo-Ferreira JPC. Vulnerabilidade à poluição de águas subterrâneas: Fundamentos e conceitos para uma melhor gestão e protecção dos aquíferos de Portugal. 4.º Lisboa: Congresso da Água; 1998.
[7] Al-Zabet T. Evaluation of aquifer vulnerability to contamination potential using the DRASTIC method. Environmental Geology, 2002;43:203-208.
[8] Paralta EA, Francés AP, Ribeiro LF. Avaliação da vulnerabilidade do sistema aquífero dos Grabos de Beja e análise crítica das redes de monitorização no contexto da directiva da água. Paper presented at: VII Simpósio de Hidráulica e Recursos Hídricos dos Países de Língua Oficial Portuguesa - SILUSBA; 2005; Évora, 30 de Maio a 2 de Junho de 2005.
[9] Mejuto MF, Castaño S, Vela A. Utilidad de las ténicas de observación de la tierra a lá elaboración de mapas de vulnerabilidad y riesgo de contaminación de aguas subtrerráneas. Paper presented at: VIII Congresso Nacional de Teledetección; 22-24 Setiembre 1999; Albacete, Espanha.
[10] Xavier J, Gagliardi S, Vidal H, Montano M, Lucena L. Evaluación de la vulnerabilidad a la contaminación del acuífero Mercedes en el área metropolitana de la Ciudad de Paysandú – Comparación de los Métodos GOD y DRASTIC. Revista Latino- Americana de Hidrogeologia. 2004; 4:35-45.
[11] Teixeira J. Hidrogeomorfologia e sustentabilidade de recursos hídricos subterrâneos [Tese de Doutoramento]. Universidade de Aveiro e Universidade do Porto; Aveiro e Porto, 2011.
[12] Carvalho PEM, Cavaleiro VMP. Área de protecção do recurso hidromineral das termas de entre-os-rios. Paper presented at: 1st Joint World Congresso on Groundwater; 31-07 to 04-08, 2000. Fortaleza, Ceará, Brasil.
[13] Laboratório de Análises do Instituto Superior Técnico. Relatório de análise físicoquímica completa – Fundação inatel, furo dos barbeitos, situado em quinta da torre, entre-os-rios. Instituto Superior Técnico de Lisboa, Lisboa; 2018.
[14] Gonçalves V. Elaboração de perímetros de proteção de captações de águas subterrâneas com recurso a SIG [MSc thesis]. Covilhã: Universidade da Beira Interior ; 2020.
[15] Laboratório nacional de Engenharia Civil. Análise e parecer sobre a situação originada pelo derrame de hidrocarbonetos em EntreosRios. Lisboa: Laboratório Nacional de Engenharia Civil; 2008.
[16] Laboratório Nacional de Energia e Geologia. Carta Geológica de Portugal, escala 1:500.000. Serviços Geológicos de Portugal, Amadora, 1992. Available from: https://sig.lneg.pt/server/services/CGP500k/MapServer/WMSServer
[17] Direcção Geral do Território. Carta de Uso e Ocupação do Solo para 2018. Lisboa, 2019. Available from: http://mapas.dgterritorio.pt/wmsinspire/ cos2018v1?service=WMS&REQUEST=GetCapabilities&VERSION=1.3.0
[18] Singhal BBS, Gupta RP. Applied hydrogeology of fractured rocks. 2nd ed. Dordrecht: Springer; 2010.
[19] Lencastre A, Franco FM. Lições de hidrologia. 2nd ed. Universidade Nova de Lisboa; Lisboa, 1992.
[20] Calado C. A ocorrência de água sulfúrea alcalina no Maciço Hespérico: Quadro hidrogeológico e quimiogénese [PhD thesis]. Lisbon: Universidade de Lisboa; 2001.
[21] Diário da República. Decreto-Lei n.º 382/99 de 22 de Setembro do diário da República n.º 222, I série. Delimitação de perímetros de protecção de captações de águas subterrâneas destinadas ao abastecimento público; 1999.