Abstract:
The quality of indoor environmental plays pivotal rule to influence the microbiological growth through the air that has a significant effect on human’s respiratory health. In some regions in Indonesia, airborne diseases among productive age are still a common problem. Even though the trend of accidents increases in some provinces, it has not been the priority to overcome by the government. In 2013, the accident of acute respiratory infections (ARIs) among informal workers were taken place as the first rank of 10 most common occupational illnesses in Ciomas District, West Java Province and the prevalence experienced upward trend in four months, from June to September. Thus, this study aimed to describe the relationship between indoor
environmental quality (IEQ) and the occurrence of ARIs. The population and sample of study were all workers who worked in seven footwear workshops in Pagelaran Village, Ciomas District, Bogor Regency that employed 85 workers. The present study used a cross-sectional design to investigate whether relative humidity, illumination, and indoor temperature as the IEQ parameters have to do with worker’s respiratory health. The independent t-test was used to analyze the data that was collected in March to April 2014. The result revealed the average illumination levels at 175.586 lux (min 53.3 lux and max 367.0 lux), the average temperature levels at 30.962
References:
[1] Centers for Disease Control and Prevention. (2017). Indoor Environmental Quality. NIOSH. Retrieved from https://www.cdc.gov/niosh/topics/indoorenv/default.html (accessed on 26 December 2017).
[2] Jaromír Klemeš, J., Yen Liew, P., Shin Ho, W., et al. (2017). Influence of indoor environmental quality on work productivity in green office buildings: A review. Chemical Engineering Transactions, vol. 56. DOI: 10.3303/CET1756065
[3] Sakellaris, I. A., Saraga, D. E., Mandin, C., et al. (2016). Perceived indoor environment and occupants’ comfort in European “modern” office buildings: The OFFICAIR study. International Journal of Environmental Research and Public Health, vol. 13, pp. 1–15. DOI: 10.3390/ijerph13050444
[4] Schram-Bijkerk, D., van Kempen, E. E. M. M., and Knol, A. B. (2013). The burden of disease related to indoor air in the Netherlands: Do different methods lead to different results? Occupational and Environmental Medicine, vol. 70, pp. 126–132. DOI: 10.1136/oemed-2012-100707
[5] Kembel, S. W., Meadow, J. F., O’connor, T. K., et al. (2014). Architectural design drives the biogeography of indoor bacterial communities. PLoS One, vol. 9. DOI:10.1371/journal.pone.0087093
[6] Fitria, L., Wulandari, R. A., Hermawati, E., et al. (2008). Kualitas Udara dalam Ruang Perpustakaan Universitas “X” ditinjau dari Kualitas Biologi, Fisik, dan Kimiawi. Makara Kesehat, vol. 12, pp. 76–82.
[7] Abdullah, M. T. and Hakim, B. A. (2011). Lingkungan Fisik dan Angka Kuman Udara Ruangan di Rumah Sakit Umum Haji Makassar, Sulawesi Selatan. J Kesehat Masy Nas, vol. 5, pp. 206–211.
[8] Puskesmas, U. P. T. (2014). Ciomas. Laporan Bulanan Program Kesehatan Kerja Tahun 2013. Bogor.
[9] Seppanen, O. A. and Fisk, W. J. (2006). Some Quantitative Relations between Indoor Environmental Quality and Work Performance or Health. Lawrence Berkeley Natl Lab.
[10] Lubart, R., Lipovski, A., Nitzan, Y., et al. (2011). A possible mechanism for the bactericidal effect of visible light. Laser Therapy, vol. 20, pp. 17–22. DOI: 10.5978/islsm.20.17
[11] Syam, D. M. and Ronny. (2016). Suhu, Kelembaban dan Pencahayaan sebagai Faktor Risiko Kejadian Penyakit ISPA pada Balita di Kecamatan Balaesang Kabupaten Donggala. Higiene vol. 2, pp. 133–139.